    <title locale="en_US">Investigating the Reliability of the Measurement of the Cervical Muscle&#x2019;s Echo Intensity</title>
    <FirstPage>106</FirstPage>
    <LastPage>113</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Sedighe Sadat</FirstName>
        <LastName>Naimi</LastName>
        <affiliation locale="en_US">Physiotherapy Research Center, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Fateme</FirstName>
        <LastName>Bokaee</LastName>
        <affiliation locale="en_US">Department of Physiotherapy, School of Rehabilitation Sciences, Isfahan University of Medical Sciences, Isfahan, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>07</Month>
        <Day>13</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>11</Month>
        <Day>21</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Introduction: The skeletal muscle&#x2019;s echo intensity (EI) is a measurement that can be used to assess the quality of the muscle and any muscle damage caused by training or activity. To determine its reliability, a limited number of studies have investigated the measurement of cervical muscles&#x2019; EI. This study determines whether the EI of the cervical muscles can be reliably quantified using the Adobe Photoshop software.
Materials and Methods: The mean EI of the cervical muscles was measured using the standard histogram function of Adobe Photoshop CS6 in 20 healthy women.
Results: The measurement of EI of cervical muscles using Adobe Photoshop CS6 is reliable in healthy women (intra-class coefficient &gt;0.9). The values of the standard error of measurements of longus coli, sternocleidomastoid, levator scapula, semispinalis capitis, rectus capitis posterior, and oblique capitis superior muscles were 1.81, 2.09, 1.46, 2.02, 1.47 and 1.26, respectively. The values of the smallest detectable difference of longus coli, sternocleidomastoid, levator scapula, semispinalis capitis, rectus capitis posterior, and oblique capitis superior muscles were 7.11, 8.22, 5.74, 7.93, 5.79, and 4.97, respectively.&#xA0;
Conclusion: Assessing the EI of the cervical muscles with Adobe Photoshop software is a viable method to determine the quality of the muscles.</abstract>